The certificate

Named to the standard, measured to the benchmark — or it isn't evidence.

After a kitchen fire, a claims assessor asks six things: what was done, when, to what standard, measured how, by whom, and what was known to be outstanding. An invoice answers none of them. A Summit Certificate answers all six from the document alone.

01  What every certificate contains

Nine things,
without exception.

The standard and the benchmark, attributed honestly

AS 1851-2012, routine service of fire protection systems and equipment, Section 13 — fire and smoke control features of mechanical services — is the only edition cited. The acceptance benchmark, mean grease depth below 0.2 mm (200 μm) and no single reading above 2 mm (2,000 μm), is the AIRAH Best Practice Guideline (Commercial Kitchen Exhaust Management) benchmark, and is attributed to it.

Readings at every access point

A micron-scale grease-depth reading at every duct access point opened, position-labelled, before and after works. Where deposit is uneven, the reading is taken at the heaviest accumulation within reach — the worst point is the honest point.

Identical-position photographs

Every photographed position is re-shot after works from the same position and framing. One label per pair, matching the reading labels.

Full-vs-partial disclosure

Whether the entire system was serviced or only part of it, stated plainly, with every section not accessed listed and the reason — no access panel, structural obstruction, tenancy constraint.

A numbered deficiency register

Every deficiency observed, with a sequential number, location, severity (Critical, Major or Minor), photographic reference, recommended action and a recommended re-inspection or rectification interval.

Exactly two statuses

Compliant: every serviced section meets the criteria and no limitation was recorded. Compliant with limitations: the works meet criteria where performed and every outstanding item is listed on the certificate itself. Never a third, softer word.

The interval statement

Your servicing interval is set at the site survey from cooking load, fuel type, hours and the measured grease accumulation between services, and is written on your certificate. No Summit document asserts a servicing frequency on the standard's behalf.

Identity and traceability

Certificate number, venue, service date, service category, the attesting entity and the technician who performed the works.

Numbering

SAM-CERT-####: four digits, strictly sequential, never reused, never reissued under the same number. A superseding certificate takes a new number and names the one it replaces.

02  The specimen

What lands
on your desk.

A specimen, watermarked, with illustrative values. The layout and the elements are exact; no site, date or finding on it is real.

01Status is derived from the works report, never chosen.
02Every register row cites a captured, position-labelled photograph.
03Nothing is certified that the works report does not record.
SUMMITAsset Maintenance
Certificate of Service · Kitchen Exhaust System · Specimen

Serviced & certified to AS 1851-2012

Certificate no.SAM-CERT-0000-SPEC
StatusCompliant with limitations — listed below
Site[Venue & address]
Service date[Date of service]
StandardAS 1851-2012 · Section 13
BenchmarkAIRAH Best Practice Guideline
ScopeFull system, except riser above AP-3
Next service[Set from measured accumulation]
PositionBeforeAfterResult
AP-1 · canopy plenum1.4 mm0.1 mmWithin criteria
AP-2 · horizontal run0.9 mm0.1 mmWithin criteria
AP-3 · riser base2.6 mm0.2 mmWithin criteria
Riser above AP-3——Not accessed · register #1

Benchmark: AIRAH Best Practice Guideline (Commercial Kitchen Exhaust Management) — mean grease depth below 0.2 mm (200 μm), no single reading above 2 mm (2,000 μm). Never attributed to AS 1851-2012. Illustrative values; readings in mm (1 mm = 1,000 μm).

#LocationSeverityObservationPhotoRecommended action
1Riser above AP-3MajorNo access panel — section not accessedAP-3-B2Install access panel; service on next visit
2Fan discharge cowlMinorGrease trail at dischargeFAN-B1Fit rooftop containment; monitor
Certified by
[Attending technician]
Summit Asset Maintenance · Adelaide
Cross-reference
Works report + photo set
issued with this certificate
03  The works report

Component by
component.

The certificate summarises; the works report walks the whole system — canopy, filters, plenum, each access point, riser, fan and discharge — with its readings, its photo pair and its result per line. It is written to be read in two minutes by someone who was not there.

01Every component with its own before-and-after readings.
02Photo pair referenced per line; borescope frames in both directions at each access point.
03Sections not accessed carried into the disclosure — captured on site, not reconstructed later.
Summit · Works Report · Specimen

Kitchen Exhaust — Component by component

Standard AS 1851-2012 · Section 13Benchmark AIRAH Best Practice GuidelinePhoto pairs Identical positionBorescope Both directions, each access point
ComponentBeforeAfterPhoto
Canopy & filters1.1 mm0.1 mmCAN-B1 / A1
AP-1 · canopy plenum1.4 mm0.1 mmAP-1-B1 / A1
AP-2 · horizontal run0.9 mm0.1 mmAP-2-B1 / A1
AP-3 · riser base2.6 mm0.2 mmAP-3-B1 / A1
Riser above AP-3Not accessed—AP-3-B2 · register #1
Fan chamber & discharge0.7 mm0.1 mmFAN-B1 / A1
Readings against the AIRAH benchmarkIllustrative values, in mm (1 mm = 1,000 μm)
04  Where it goes

Built for the three people
who will ask for it.

YOUR INSURER

When the claim comes

Maintenance records are among the first documents requested after a kitchen fire. A certificate that carries its own readings, photographs and register can be read without a phone call; one that does not invites dispute.

YOUR FORM 3 SIGNATORY · SA

When the verification is due

Where the exhaust system sits on a building's Essential Safety Provisions schedule, the owner's annual Form 3 relies on maintenance evidence. Summit's certificate is built to hand straight across.

YOUR AUDITOR

When the audit lands

Council, food-safety and internal audits ask the same question: can you produce the records? Per site, current, and produced on request.

05  How the record is held

Issued to you.
Kept per site.

Per-site register

Every certificate, works report and photo set is filed against the site and the component it describes — the record outlives the visit.

QR-tagged assets

Canopies, access panels and key components are tagged at first service, so a record can be found from the asset itself, not just from a filing system.

History on request

A component's full service history, readings and photographs are produced on request — for the audit, the claim or the handover.

Portfolio roll-up

For groups, the same records are consolidated across every site so the whole position can be read at once.

Start

Evidence from the first visit.

Start with a site survey — the same instruments, the same benchmark and the same evidence discipline as the certificate, on your own kitchen.

enquiries@summitam.au