Commercial kitchen compliance, maintained with certainty.

  • AS 1851-2012 maintenance regime
  • AIRAH best-practice grease benchmark
  • SAM-CERT numbered, every visit

Kitchen exhaust systems maintained on a planned interval program. Every visit closes with grease-depth readings at every access point, identical-position before-and-after photographs and a numbered deficiency register — the compliance record is the product.

Book a site survey → See the certificate The site survey will be free for hospitality groups, aged care and managed venues in metro Adelaide, and available as a paid condition report otherwise.
SUMMITAsset Maintenance
Certificate of Service · Kitchen Exhaust System · Specimen

Serviced & certified to AS 1851-2012

SAM-CERT-0000-SPEC · Compliant with limitations — listed below · Site: [Venue & address] · Date: [Date of service]

PositionBeforeAfterResult
AP-1canopy plenum1.4 mm0.1 mmWithin criteria
AP-2horizontal run0.9 mm0.1 mmWithin criteria
AP-3riser base2.6 mm0.2 mmWithin criteria
Riser above AP-3——Not accessed · register #1

Benchmark: AIRAH Best Practice Guideline (Commercial Kitchen Exhaust Management) — mean grease depth below 0.2 mm (200 μm), no single reading above 2 mm (2,000 μm). Never attributed to AS 1851-2012. Illustrative values; readings in mm (1 mm = 1,000 μm).

#LocationSeverityRecommended action
1Riser above AP-3MajorInstall access panel; service on next visit
2Fan discharge cowlMinorFit rooftop containment; monitor
Specimen · illustrative valuesSee the certificate →
The shift

Kitchen exhaust certificates are commonly self-declared. Summit's reports the measurements.

A sticker on the canopy and a sentence on an invoice say a visit happened. They say nothing about the duct run the sticker never saw, nothing an assessor can verify after a fire, and nothing about what was left outstanding.

Summit maintains commercial kitchen exhaust systems under AS 1851-2012 and certifies every visit with the readings, the photographs and the register on the page — evidence your insurer, your Form 3 signatory and your board can read without calling anyone.

  • Readings in microns, not adjectives
  • Photographs from identical positions
  • Next service set before the technician leaves
01  The certificate

Named to the standard,
measured to the benchmark.

Every Summit Certificate carries the same nine elements, without exception. Five of them are below; the full specimen shows all nine. The certificate summarises; behind it sits the works report and the numbered deficiency register its status is derived from. A certificate that cannot show its readings is not issued.

01Grease-depth readings in microns at every access point, before and after works.
02Before-and-after photographs from identical positions — one label per pair.
03Full-vs-partial disclosure: every section not reached, listed with the reason.
04A numbered deficiency register — location, severity, photo reference, recommended action.
05Exactly two statuses: Compliant, or Compliant with limitations — listed on the certificate itself.

See the full specimen certificate →

Summit · Works Report · Specimen

Kitchen Exhaust — Component by component

Certificate SAM-CERT-0000-SPECStandard AS 1851-2012 · Section 13Benchmark AIRAH Best Practice GuidelinePhoto pairs Identical position
ComponentBeforeAfterPhoto
Canopy & filters1.1 mm0.1 mmCAN-B1 / A1
AP-1 · canopy plenum1.4 mm0.1 mmAP-1-B1 / A1
AP-2 · horizontal run0.9 mm0.1 mmAP-2-B1 / A1
AP-3 · riser base2.6 mm0.2 mmAP-3-B1 / A1
Riser above AP-3Not accessed—AP-3-B2 · register #1
Fan chamber & discharge0.7 mm0.1 mmFAN-B1 / A1

Benchmark: AIRAH Best Practice Guideline (Commercial Kitchen Exhaust Management) — mean grease depth below 0.2 mm (200 μm), no single reading above 2 mm (2,000 μm). Never attributed to AS 1851-2012. Illustrative values; readings in mm (1 mm = 1,000 μm).

Deficiency register · numbered, carried onto the certificate
#LocationSeverityPhotoRecommended action
1Riser above AP-3MajorAP-3-B2Install access panel; service on next visit
2Fan discharge cowlMinorFAN-B1Fit rooftop containment; monitor
Readings against the AIRAH benchmarkStatus derived from this report
02  The program

One interval program.
Every visit ships the evidence.

SET AT SURVEY

Your interval, from your kitchen

Set from cooking load, fuel type, hours and the measured grease accumulation between services — written on your certificate, never assumed from a table.

SCHEDULED AHEAD

Nothing floats

The year's schedule is issued up front, a reminder arrives before every visit, and the next service is set before the technician leaves site.

ONE LINE, MONTHLY

Every visit ships its evidence

Programs are billed calendar-monthly in arrears. Each visit ships its works report, photo pairs, certificate and updated register.

How the program runs →

03  Who it is for

Built for the venues
where the record matters.

HOTEL GROUPS

Many kitchens, one file

Accreditation and insurer renewal across every venue, read from one consolidated record.

AGED CARE

The heaviest scrutiny

Standing obligations, regular audit, and a resident population that cannot evacuate quickly.

CENTRE FOOD COURTS

The landlord's schedule

Tenancy kitchens on the building's essential safety provisions, evidenced for the owner's Form 3.

VENUE OPERATORS

The board's risk register

Licensed venues and clubs where the exhaust line sits on a risk register someone has to sign.

FACILITIES MANAGERS

One record per site

Portfolio-wide visibility of what was measured, what was found, and what is still open.

Single venues and small groups are welcome. Programs are shaped by venue count — 1 · 2–5 · 6+ — and the free site survey applies inside that profile.

04  The site survey

Start with the survey.
Keep the report either way.

A 15–30 minute measured walk of your exhaust system with the same instruments the certificate uses — grease-depth comb, borescope, tripod light, camera. You receive a written condition report and a numbered deficiency schedule whether or not you engage Summit.

01Free for hospitality groups, aged care and managed venues in metro Adelaide.
02Available as a paid condition report for everyone else — same protocol, same instruments.
03The report measures the asset. It never names, grades or characterises any provider.

What happens at the survey →

Summit · Site Survey Report · Specimen

Kitchen Exhaust — Condition

Reference SAM-SVY-0000-SPECDuration 15–30 min · one passInstruments Comb · borescope · cameraProvided Without charge or obligation
Checklist itemCaptured
Canopy & filtersCondition · photos
Duct access pointsReadings in microns · borescope
Fan & dischargeCondition · photos
Access constraintsRecorded · confined-space screen
Compliance evidenceRecords sighted, or absence recorded
Deficiency schedule attachedReport kept by the venue
South Australia

Own a commercial building in SA? The kitchen exhaust line on your Form 3 needs evidence behind it.

Building owners lodge the Essential Safety Provisions maintenance verification within 60 business days of the calendar year's end. A signature on the strength of an unmeasured exhaust system is one the owner cannot stand behind.

Form 3, in plain English →
For referrers

For the people who see the grease before anyone else.

Insurance brokers, fire-suppression technicians, kitchen installers and food-safety consultants — the certificate makes your sign-off easier, and the register hands work in your scope back to you in writing.

How a referral works →
The film

The asset,
surveyed.

Ten seconds, no narration. A form in the dark, measured line by line until its shape is known — which is the whole of what Summit does, before any of it is written down.

10 seconds · sound on
Start

Start with the survey.

A measured walk of the system, a written report you keep, and a program proposal built from the deficiency schedule — a maintenance partner accountable for the record, not the cheapest cleaner.

enquiries@summitam.au